The Walling Company of Iowa

Balance

Balance

Typical balancing applications include:

  • Rock Crushers
  • Cooling Towers
  • Hammer Mills
  • Grinders
  • Centrifuges
  • Fans
  • Shredders
  • Pulverizers
  • Rolls
  • Couplings
  • Pulleys
  • Impellers
  • Rotors
  • Armatures
  • Turbines
  • Compressors
  • Mixers
  • etc…


Hammermill


Centrifuigal Fan


ID Fan


Cooling Tower

Balance Report – Summary

Balance Report - Summary
Report Date: 02-May-05
Equipment: H-10 BACKUP GRINDER
Job Number: H10
Data: 28-Apr-05 11:15:27
Shaft Number: 1
Status: ACCEPTABLE
Tolerance Spec: 1.000
Units: mils Pk-Pk

 

Plane Meas Pt Start Mag End Mag % Reduction

1

IBH

6.195

0.977

84

1

IBV

3.025

0.716

76

2

OBH

1.969

0.840

57

2

OBV

4.410

0.906

79

Tolerance Acceptance Chart

 



 

 

Example of cost saving after balancing fan.
480V electrical system, $.06 kw/hr, 24-7-365 operation, a three amp decrease on any piece of equipment equates to $1,252.83 per year savings. Balancing pays for itself.